Fire-fighting equipments

The fire-fighting pressure equipments are used to supply installations containing extinction elements like sprinklers (ROC), built under the UNE 12.845: 2005 standard, equipped fire hydrants (BIE) or columns of hydrants (CHE) built under UNE 23.500: 2012 standard. The equipments can also be constructed under the Technical Rule CEPREVEN.

  • Fire-fighting pressure equipments GCI ranges basically composed of a main centrifugal pump, an auxiliary pump (optional depending on the standard), a \\"jockey\\" electro-pump and one or more electric panels for signaling, control, alarm and maneuver.

GCI

Fire-fighting equipments

APPLICATIONS
  • Currently there are two different fire-fighting equipments: those for the supply of installations containing extinguishing elements through sprinkles (ROC), manufactured under the standard UNE-12.845, and those for equipped fire hydrants (BIE) or standpost hydrants (CHE), manufactured under current standard UNE-23.500:2012.
  • In addition, the equipments can also be assembled under the Technical Regulation CEPREVEN RT2- ABA, valid for any possible extinguishing combination. Despite not being considered as a national mandatory rule, it was the normative model while there was not a clear legislation in this sector.
COMPONENTS
  • Main pump: must be activated in case of fi re and can only be stopped manually. This pump must be capable to propel minimum 140% of the nominal fl ow at a pressure not lower than 70% of the nominal pressure.
  • Booster pump: same hydraulic characteristics as the main pump, electrical or diesel, its installation is needed when a back-up power supply is demanded due to the installations characteristics.
  • Jockey pump: it is used to keep the fi re-fi ghting equipment pressurized, balancing out the possible leaks in the installation avoiding the start up of the main pump. It starts and stops through a signal from the pressure switch, adjusted between two pressure values.
  • Electric switchboards according to constructive standards for the start and control of the pumps.
  • Check and shut-off valves in every pump.
  • Wide size range of general discharge manifolds.
  • Pressure switch for manoeuvre.
  • Pressure switch and safety valve for carried escape.
  • Galvanized sheet base plate.
  • 24 liters HASABOX changeable membrane tank, stamped at a pressure higher than the maximum pressure of the circuit.
  • Glycerin manometer.
  • Sample manifold with insertion fl owmeter (optional).
  • All equipments are provided assembled over base plates and in-factory electrically tested.