SWITCHMATIC
Electronic pressostats
SWICHMATICNew electronic pressure switch with integrated digital pressure sensor and manometer.Version 2 for full control and protection of the pump, replacing the functions of the pressure switch, pressure gauge, electrical protection panel and level switch.Version 3 is used through an electrical panel similar to that of a conventional pressure switch.
TECHNICAL CHARACTERISTICS
SWITCHMATIC 2Supply voltage: 1~110/230 Vac (50/60Hz)I max.: 16A (230V), 30A (110V) P. Start: 0,5 - 7,0P. Stop: 1,0 - 8,0Min. Differential: 0,5 - 1,5Factory settings: 3,0 - 4,0Connection: G 1/4" H/FIP: 55Max. temp. Water: 50ºC
SWITCHMATIC 2TSupply voltage: 3~230/400 Vac (50/60Hz)I max.: 10A (400V), 16A (220V) P. Start: 0,5 - 11,5P. Stop: 1,0 - 12,0Min. Differential: 0,5Factory settings: 3,0 - 4,0Connection: G 1/4" H/FIP: 55Max. temp. Water: 50ºC
SWITCHMATIC 3Supply voltage: 1~48/230 Vdc/Vac (50/60Hz)I max.: 10AP. Start: 0,5 - 7,0P. Stop: 1,0 - 8,0Min. Differential: 0,5 - 1,5Factory settings: 3,0 - 4,0Connection: G 1/4" H/FIP: 55Max. temp. Water: 50ºC
KIT SWITCHMATIC 2New 3-way fitting with built-in SWITCHMATIC-2 electronic pressure switch system and check valve.To be directly installed with the electro-pump.
TECHNICAL CHARACTERISTICSType: Electronic pressure switch KitSupply voltage: 1~110/230 Vac (50/60Hz)I max.: 16A (230V), 30A (110V) IP: 55Max. temp. Water: 50ºCConnexions: G 1"H x 1"H x 1"M
ADVANTAGESBuilt-in digital manometer with reading in bar and psi (3-digit display)Easy pressure adjustment for the start and stopInstantaneous current reading (A)Protection agains lack of water by consumed currentProtection against overcurrentProtection against fast operation cyclesSynchronizable for 2-pumps equipments with alternationManual commisioning buttonAutomatic restart (ART function) and manual (RESET)Operation as conventional pressure switch or inverted (NO/NC).Voltage-free contact to monitor alarmsStandby mode with low power consumption
PRESOSTATOS
Electromechanical Pressostats
APPLICATIONSPressure switches for start and stop of pumps, with 1/4'' GAS female thread with minimal pressure controls of 0,9 kg/cm2 and maximal of 12 kg/cm2
LOGICPRESS
Electronic pressure regulators
OPERATIONElectronic controller for automatic control of pumps without maintenance. It keeps the pump connected while there is a water consumption, providing a constant pressure depending on the required flow.This device replaces the traditional system of hydropneumatic tank and pressure switch, thus avoiding the typical problems like lack of air in the expansion vessel or incorrect adjustment of the pressure switch.
TECHNICAL CHARACTERISTICSType: Pressure controllerCompliance: CECertification: TÜVSupply voltage: 1~230Vac ±10% (50Hz), 1~115Vac ±10% (60Hz)I max.: 8A (50 Hz), 16A (60 Hz)IP: 65Temp. max. (ºC): 65
ADVANTAGESProtection in case of lack of water: Disconnects the pump to avoid running dryAutomatic restart in case of blockade: During the following 24 hours after the blockade, the machine performs ten double attempts to restart, lasting about 5 seconds each attempt, to pressurize the installation again.Antilock function: If the pump is not used for 24 consecutive hours, the device starts the engine for about 5 seconds. Should it continue inactive, this operation will be repeated every 24 h.Electronic adjustment of the start pressure (SET version only) 1.5 BAR / 2 BAR / 2.5 BAR.Possibility to supply manometer and wiring integrated or separately.
PRESSCONTROL
Pressure regulator
OPERATIONThe main difference between the pressure controller and traditional systems of hydropneumatic tanks, is that the pressure controller keeps the pump connected while there is power supply consumption, ensuring constant pressure according to the requested flow.On the other hand, in the traditional system, pressure constantly varies according to accumulated water volume in the hydropneumatic tank.Foot or check valve for the pump suction is required. Likewise, the installation of a shut-off valve in the discharge is recommended.If the water column between the pump and the highest supply point is over 15 mts., the controller can not be directly mounted on the pump, it should be inserted between the pipe.
ADVANTAGESConstant pressure (according to requested flow)Replaces membrane tank, pressure switch, 5-way fi tting and level switchProtection in case of lack of water: Disconnects the pump to avoid running dryProtection against lack of a phase on the supply or accidental inversion of a phase (MASCONTROL-UP): In this case the device detects the anomaly and maintains the correct direction of rotation of the pump.Reduced dimensions in all the booster.Completely silent operationPush-button for manual controlBuilt-in check valveAdjustment and maintenance is not neededNota: Starting-up pressure, supply power (12-24-220 v.) and the membrane for using the controller in gas-oil transfers can be modified upon request.
SPEEDBOARD
Pump driver with variable-frequency drive
OPERATIONThe pump controller with variable-frequency-drive SPEEDBOARD is suitable for operating with three-phase pumps and can be installed directly over the terminal box of the pump motor to be controlled. Simple motor specification configuration, as the user only has to set up pressure adjustment and nominal intensity.It can be mounted individually or in groups of up to 4 pumps in parallel communicated and operating in MASTER-SLAVE mode with alternated sequence of operation.
TECHNICAL CHARACTERISTICSControl panel with LCD screen with warning leds, START/STOP and AUTOMATIC push buttons.Configuration system for easy and intuitive programming.Pressure reading through external pressure transducer.Intensity current sensor with instantaneous reading.Protections agains lack of water by consumed current, overcurrent, fast operating cycles and abnormal supply voltage.ART function (Automatic Reset Test), which connects the pump with a programmed periodicity until the water supply has been restored.Register of alarms and operational controls (working hours, start counter, connections to the electrical network counter).Automatic restart system after an interruption of power supply keeping the configuration parametres.It’s possible to connect a level switch as protection. This system is independent from the safety system against dry running operation.Cooling by forced convection by the fan of the motor with an intelligent temperature management system.
SPEEDBOX
Wall-mounted pump driver with variable-frequency drive
OPERATIONThe pump controller for wall assembly with variable-frequency-drive SPEEDBOX is suitable for operating with single-phase and three-phase pumps.Simple motor specification configuration, as the user only has to set up pressure adjustment and nominal intensity.It can be mounted individually or in groups of up to 4 pumps in parallel communicated and operating in MASTER-SLAVE mode with alternation.
TECHNICAL CHARACTERISTICSControl panel with LCD screen with warning leds, START/STOP and AUTOMATIC push buttons.Configuration system for easy and intuitive programming.Pressure reading through external pressure transducer.Intensity current sensor with instantaneous reading.Protections agains lack of water by consumed current, overcurrent, fast operating cycles and abnormal supply voltage.ART function (Automatic Reset Test), which connects the pump with a programmed periodicity until the water supply has been restored.Register of alarms and operational controls (working hours, start counter, connections to the electrical network counter).Automatic restart system after an interruption of power supply keeping the configuration parametres.It’s possible to connect a level switch as protection. This system is independent of the safety system against running dry operation.Cooling system by forced convection (fan).
SPEEDBOXDUO
Double-pump wall-mounted driver with variable-frequency drive
OPERATIONCompact wall-mounted controllers for the control of 2-pump booster sets.SPEEDBOX DUO: Device for single-phase power supply. Each pump has its own variable-frequency drive, which makes the pumps work alternately and in cascade.SPEEDBOX DUO SET: Device for three-phase power supply. It has a variable-frequency drive to control the main pump and a power relay to control the auxiliary pump. The operation is alternating, in each cycle of operation the first pump to start changes and it is always controlled by the drive.
TECHNICAL CHARACTERISTICSAlternate operating sequence of the pumps.Control panel with LCD screen with warning leds, START/STOP and AUTOMATIC push buttons.Configuration system for easy and intuitive programming.Pressure reading through external pressure transducer (included with drive).Intensity current sensor with instantaneous reading.Protections agains lack of water, overcurrent, abnormal supply voltage, shortcircuits and failure of transducer.ART function (Automatic Reset Test), which connects the pump with a programmed periodicity until the water supply has been restored.Register of alarms and operational controls (working hours, start counter, connections to the electrical network counter).Automatic restore system after an interruption of power supply keeping the configuration parametres.It's possible to connect a level switch as protection. This system is independent from the safety system against dryrunning operation.Cooling system by forced convection (fan).
ECOVAR
Pump driver with speed variator
OPERATIONECOVAR pump driver manages and protects pressure equipments up to 3 pumps, by means of a reliable electronic control system. Besides, constant pressure is achieved regardless of the flow request, changing the motor speed by means of an INVERTER system in the control of power.Main pump regulated by INVERTER and auxiliary pump/s in cascade through direct starting-up (alternation only between auxiliary pumps).
TECHNICAL CHARACTERISTICSControl panel with LCD screen with warning leds, START/STOP and AUTOMATIC push buttons.Configuration system for easy and intuitive programming.Pressure reading through internal pressure transducer.Intensity current sensor with instantaneous reading.Protections agains lack of water by consumed current, overcurrent, fast operating cycles and abnormal supply voltage.ART function (Automatic Reset Test), which restarts the pump with a programmed periodicity until the water supply has been restored.Register of alarms and operational controls (working hours, start counter, connections to the electrical network counter).Automatic restart system after an interruption of power supply keeping the configuration parametres.It’s possible to connect a level switch as protection. This system is independent from the safety system against dry running operation.
CARTUCHOSKIT
Filters for water
APPLICATIONSThe cartridge filters are suitable for removing solid suspended particles or any bad taste in water in domestic and industrial installations.
CARTRIDGE-HOLDERMade up of two-piece head with purge valve and 1’’ connecting fitting in brass, transparent vessel for control and checking of 9 3/4’’ (248 mm) standard cartridges. All components are manufactured in food grade materials.The installation of a pressure reducing valve before cartridge-holder is recommended for shock absorption.
WOUND YARN CARTRIDGECartridge suitable for the elimination of particles or suspended foreign bodies in water. Disposable.
WASHABLE NET CARTRIDGECartride suitable for suspended particle filtration, industrial machinery protection, prefilter and postfilter for pumps. Washable
ACTIVE COAL CARTRIDGECartridge suitable for chlorine elimination and chlorinated compounds producing unpleasant taste and smell in drinking water
POLYPHOSPHATE SALTS CARTRIDGECartridge suitable for lime elimination and pipe protection, installation at water inlet for household appliances is recommended.
FILTROSRED
Network and water softening filters
DOSAL WATER SOFTENER 3/4''
APPLICATIONSWater softener made of non-toxic materials intended for household use for preventing limescale and the corrosion of washing machines. Easy to install. Replace the polyphosphate load approximately once every six months if it has not dissolved before.
TECHNICAL CHARACTERISTICSType: Water softenerMax. Flow: 1.000 l/hMax. pressure: 7 BARTemp. max.: 35 ºCMax. Hardness water: 50 ºF (500ppm CaCo3)Polyphosphate content: 150 grConnections: 3/4”Dimensions: 70x130 mm
MATERIALSHead: Reinforced polypropylene
Transparent container: SAN
O'ring: EPDMFlat joints: PVCMICRO FILTER 3/8''Small foreign bodies filter made of non-toxic materials for the protection of valves, industrial machines, and irrigation installations.
TECHNICAL CHARACTERISTICSType: Foreign bodies filterMax. Flow: 500 l/hMax. pressure: 7 BARTemp. max.: 45 ºCFiltering degree: 300 micrasConnections: 3/8”Dimensions: 75x50x65 mm
MATERIALSHead: Reinforced polypropylene
Transparent container: SAN
O'ring: EPDMWashable filtering cartridge: ‘AISI 304’ Stainless steel
POLYPHOSPHATE SALT PACK 0.5 KG.
HASABOX
Replaceable membrane tank
APPLICATIONSChangeable membrane tanks.Suitable for installations of pressure boosters.
TECHNICAL CHARACTERISTICSType: Changeable membrane tanksCapacity (L): 5 - 700Max. pressure (BAR): 8 - 25Temperature (ºC): -5 / +90Certification: ISO:9001Official approval: CE
MATERIALSTank: Pressed steel with exterior paintMembrane: Food-nontoxic EPDMFlange: Galvanized steelNota: Please contact our technical department for different volumes or pressures.
HASABOX-MF
Multifunctional fixed membrane tanks thanks
APPLICATIONSMulti-purpose fixed membrane tanks.Thanks to its construction, suitable for sanitary water installations, heating systems or solar circuit installations.
TECHNICAL CHARACTERISTICSType: Multi-purpose fixed membrane thanks.Capacity (L): 2 - 150Max. pressure (BAR): 10Max. temperature (ºC): 100Official approval: PED-CE-2014/68/EUGuarantee: 3 years
MATERIALSExternal finish of the tank: Double layer Epoxy + Polyurethane Acrylic.Inside tank: Food-grade polypropilene liner.Membrane: Food-grade ButylWater connection: Stainless steel.
GALVANIZADOS
Galvanized hydropneumatic tanks
APPLICATIONSGalvanized tanks suitable for pressure boosters installations. Water sheet is in direct contact with the pressure-air top chamber. Continuous air renewal is carried out by injectors.
TECHNICAL CHARACTERISTICSType: Galvanized hydropneumatic tanksCapacity (L): 100 - 2000Max. pressure (BAR): 8 - 10Temperature (ºC): -10 / +60Official approval: 2014/68/UE
MATERIALSTank: Steel sheet with hot galvanized treatmentAISI 316 stainless steel tanks can be provided upon request.Nota: Please contact our technical department for different volumes or pressures.
INYECTORES
Air ejectors
APPLICATIONSAir injectors for galvanized hydropneumatic tanksNota: All models are provided with flexible hose.
HIDROCARBUROS
Expansion vessel for hydrocarbure
APPLICATIONSFixed membrane expansion vessel.Fixed membrane expansion vessel for installations of pressure boosters for hydrocarbons.
CE Approved and in accordance with 2014/68/UE standard.Not suitable for methanol or ethanol.
MATERIALSTank: Pressed steel with epoxy red exterior paintMembrane: NBR
CHALLENGER
Membrane Hydropneumatic tank
APPLICATIONSFixed membrane hydropneumatic tanks.Membrane is fixed on the tank wall by a steel ring. Air valve in brass, sealed by an O-ring cap in order to prevent air leakage.The CHALLENGER version includes a double fixed membrane system, which reduces the condensation problems.Free of maintenance.Suitable for hot water installations.CE / FDA (membrane) official approval.5-year guarantee.
MATERIALSInside tank: Virgin polypropylene claddingOutside tank: Finishing with polyurethane paint on epoxy baseMembrane: Butyl 100% chlorine resistantWater connection: Stainless steel
PRESSUREWAVE
Membrane Hydropneumatic tank
APPLICATIONSFixed membrane hydropneumatic tanks. Membrane is fixed on the tank wall by a steel ring. Air valve in brass, sealed by an O-ring cap in order to prevent air leakage. Free of maintenance.Suitable for hot water installations.CE / FDA (membrane) official approval.5-year guarantee.
MATERIALSInside tank: Virgin polypropylene claddingOutside tank: Finishing with polyurethane paint on epoxy baseMembrane: Butyl 100% chlorine resistantWater connection: Stainless steel(versión H) Pump support: Nylon(versiones H - V) Tank’s support base: Termic plastic
C2LITECAD
Membrane Hydropneumatic tank
APPLICATIONSC2 - Lite CAD tanks are not made of steel so they can not oxidize. Maintenance jobs are not needed.Easy to handle due to its low weight, designed for bearing extreme weather conditions. Membrane is fixed on the tank wall by a steel ring.Air valve in brass, sealed by an O-ring cap in order to prevent air leakage.
TECHNICAL CHARACTERISTICSType: Membrane Hydropneumatic tanksMembrane: Double (CAD-2 patented technology)Capacity (L): 60 - 450Max. pressure (BAR): 8,6Temp. max. (ºC): 50Official approval: CE / FDA (membrane)Guarantee: 5 years
MATERIALS
Outside tank: Fiberglass cloth sealed with epoxi resinMembrane: Butyl 100% chlorine resistantWater connection: Reinforced plasticBase of tank: Compact copolymer polypropilene
NIVELES
Level switch
“hasa 85” LEVEL SWITCHBecause of its compact structure, making system with water-resistant double chamber and final stamping with casted moplen injection at 1,25 atmospheres, make the “hasa 85” level switch have no leakage.It can be supplied with 2, 5 or 10 meters of three-polar cable (black [usual], blue and brown) and counterweight.
“KEY” LEVEL SWITCHCompact structure and composed by a simple chamber with injection in under-pressure coated polypropilene assuring complete tightness.Can be supplied with 2 metres of three-polar cable (black [usual], blue and brown) and counterweight.
“ILA” - "ILA-GASOIL" LEVEL SWITCHIts ease of use make “ILA” level switch different from the other switches. “ILA” has high performance only with the ballast, no need of counterweight, balances, pulleys, etc. Thanks to such characteristic it can be directly placed on the tank cover drilling 3 holes (2 for fixing the case on the tank cover) which will be covered by the connection caseFixing the rope stoppers for establishing required height is the only needed adjustmentConnection case is in varnishing aluminium and the cover is water-proof thanks to its rubber jointSuch devices are micro-switches with 2 springs offering top safety, corroborated by users who have been using such switch for more than 20 yearsFloater in Nylon, special for Gas-oil
“WASTE WATER” LEVEL SWITCHSealed water level up to 100 m. in depth, insensitive to humidity and condensation. Suitable for industrial use particularly for waste water with suspended solidsProvided with 5 meters of cable and counterweightExternal body in one-piece injected polyethileneInternal counterweight placed in the middle of the switch massElectrical control commutator 10A-250V c.a. with contact by micro-switch with high opening distanceSuch particular construction keeps electrical contact sensitive to commutation caused by minimum level variationsMaximum operation temperature 55 ºCUpon request it is possible to supply in version ATEX-EX with 10 m. of cable without counterweight, together with the intrinsic barrier ATEX-EX
CUADROS
Protection and operation switchboard
ELECTRIC CONTROL PANELS FOR PRESSURE EQUIPMENTSSupply voltage: single-phase 1~230V - three-phase 3~400V - three-phase 3~230V (230V control circuit)Direct Starter (DS) up to 5,5CV (4kW) and Star-Delta (SD) from 7,5CV (5,5kW)Plastic box up to 5,5CV (4kW) and metallic box from 7,5CV (5,5kW)Pump/s protection by thermal relay3-positions selector switch MAN-O-AUT (manual - OFF - automatic) for every pumpPump-on and themal switch pilotsPumps alternation sequence by means of relay RRA2Operation by pressure switches (1 or 2) + level switch (protection)
ELECTRIC CONTROL PANELS FOR WASTE WATERSupply voltage: single-phase 1~230V - three-phase 3~400V - three-phase 3~230V (230V control circuit)Direct Starter (DS) up to 5,5CV (4kW) and Star-Delta (SD) from 7,5CV (5,5kW)Plastic box up to 5,5CV (4kW) and metallic box from 7,5CV (5,5kW)Pump/s protection by circuit breaker3 positions selector switch MAN-O-AUT (manual - OFF - automatic) for every pumpPump-on and themal switch pilotsPilot and acoustic alarm for overlevelPumps alternation sequence by means of a relayOperation by level switches (single panel: 1 or 3 level switches / double panel: 4 level switches)On request it can be supplied with ATEX-EX intrinsic secutity barriers
ELECTRIC CONTROL PANELS WITH PROBESupply voltage: single-phase 1~230V - three-phase 3~400V - three-phase 3~230V (230V control circuit)Direct Starter (DS) up to 5,5CV (4kW) and Star-Delta (SD) from 7,5CV (5,5kW)Plastic box up to 5,5CV (4kW) and metallic box from 7,5CV (5,5kW)Pump protection by thermal relay3-positions selector switch MAN-O-AUT (manual - OFF - automatic) for every pumpPump on, themal switch, automatic mode and water shortage pilotsWELL version: Operation through 3 level probes (included) + external switch (optional)WELL-TANK version: Operation by means of 6 (3+3) level probes (included) + external switch (optional)
UNDERCURRENT ELECTRIC CONTROL PANELSupply voltage: single-phase 1~230V - three-phase 3~400VDirect Starter (DS) up to 15APlastic box with transparent coverPump protection by electronic relay (undercurrent “EIL”, undercurrent “EIH”, sub-voltage “EUL”, surge of voltage “EUH”).Easy programming of maximal intensity (IH), minimal intensity (IL) and time of restart (t)3 positions selector switch MAN-O-AUT (manual - OFF - automatic) for every pumpPump-on and automatic mode pilotsLevel control through electronic relay (Undercurrent), without need of level probes.Includes contacts for external operation by level switch and pressure switch
ELECTRIC CONTROL PANELS WITH VARIABLE-FREQUENCY-DRIVESMetallic box with forced ventilation, main switch and VFD ABB or VACONSupply voltage three-phase 3~400V (230V control circuit)Alternation by time (programmable) of the regulated pump (main pump).Auxiliary pumps with Direct Start (DS) up to 5,5CV (4kW) and Star-Delta (SD) from 7,5CV (5,5kW)Auxiliary operation by pressure switches for all pumps3 positions selector switch MAN-O-AUT for every pump and operation type (drive-0-pressure switches)Pump on, themal switch and water shortage pilotsPressure transducer 4-20 mA includedCan be supplied with level probes control for well pump (but without auxiliary operation by pressure switches)
ELECTRIC CONTROL PANELS WITH SOFT STARTERMetallic box with main switch and soft (progressive) starter ABBSupply voltage three-phase 3~400V (230V control circuit)Alternation by operation of the regulated pump (main pump).Operation by pressure switches + level switch (protection)Pump/s protection by circuit breaker3-positions selector switch MAN-O-AUT for every pumpPump on, themal switch and water shortage pilotsIt can be supplied with level probes control for well pumpIt can be supplied with level control for waste water pumps
ELECTRIC CONTROL PANELS FOR SWIMING-POOLSSupply voltage: single-phase 1~230V - three-phase 3~400V - three-phase 3~230V (230V control circuit)Direct Starter (DS)IP-55 plastic box with general differentialPump protection by magnetothermic circuit-breaker3-positions selector switch MAN-O-AUT (manual - OFF - automatic)Daily programmer in fractions of 30 min.Optionally it can be implemented with spotlights (magnetothermic + 300 W transformer + on-off switch for spotlights)
FIREFIGHTING ELECTRIC CONTROL PANELSBuilt under the different used standards (UNE 23.500:2018 / UNE 23.500:2012 / UNE 12.845 / CEPREVEN / UNE 23.500.90).Metallic box painted in red colour RAL 3000.Type of switchboard according to the pumps: EJ (electric + jockey) - E (electric) - DJ (diesel + jockey) - D (diesel).All control panels have built-in controls, signals, alarms and remote signaling, required in a special way by each one of the different standards.
DOUBLE MULTI-PURPOSE ELECTRICAL CONTROL PANELDouble multi-purpose electrical control panel to be used in booster sets or in wastewater pumping group with pumps up to 13A (all in one).It can be powered with single-phase or three-phase voltage.
Operation in Booster Sets:
- Start and stop of pumps by pressure switches.
- Protection against lack of water by level switch or by probes.Operation in Double Wastewater Pumping Groups:
- Start and stop of pumps by level switches (3 or 4) or probes (5).
- Possibility of connecting temperature and humidity probes (if the pumps include them).TECHNICAL CHARACTERISTICSSupply voltage: single-phase 1~230V / three-phase 3~400V / three-phase 3~230V.Selection of the operating mode by jumpers inside the panel.Direct starter (DS).Alternation of pumps.Box + hinges in ABS IP65 halogen-free.Protection of pumps through adjustable thermal relays up to 13A.It has 1 general magnetothermal switch + 2 contactors + maneuver fuse.Includes 7 cable glands.AUTO ON/OFF pushbuttons (activates or deactivates the manual operating mode and MANUAL button (the pump is activated while it is pressed).Indicator lights for voltage presence, pump running, operation in automatic mode, tank level and alarm.Optical and acoustic alarms for high tank level, low tank level, input failure (contradiction between pressure switches/buoys/probes), motor overload, overtemperature and humidity in the oil chamber (if the pumps have temperature and humidity probes).It incorporates a 9 Vdc output signal that can be used as a group alarm signal or as an output for a solenoid valve by means of a programmer clock.
COLECTOR
Accessories for pressure units - Collector
APPLICATIONSINOX AISI 304 manifold, polished for 2 and 3 most common dimensions pumps
DOUBLE1” x 1” x 1½”1¼” x 1¼” x 2”1½” x 1½” x 2½”2” x 2” x 3”
TRIPLE1½” x 1½” x 1½” x 3”2” x 2” x 2” x 3”
BANCADA
Accessories for pressure units - Frames
APPLICATIONSFolded galvanized-sheet frame for 1, 2 or 3 pumps
VALVULABOLA
Accessories for pressure units - Ball valves
APPLICATIONSBall-valve with INOX lever, dimensions 1" up to 4"
VALVULARETENCION
Accessories for pressure units - Retention valve
APPLICATIONSBrass retention valve with metal shutter, dimensions: 1" up to 4"
SOPORTECUADRO
Accessories for pressure units - Board support
APPLICATIONSGalvanized board support for 1, 2 or 3 pumps
GRIFOAFORO
Accessories for pressure units - Tap Gauging Pressostat
APPLICATIONS1/4'' capacity tap for pressure switch and manometer
RACORD
Accessories for pressure units - 5 opening union
APPLICATIONS5 openings fitting for pressure units, length from 91 mm to 120 mm
MANOMETRO
Accessories for pressure units - Manometer
APPLICATIONSManometer for pressure reading from 0 to 10 kg/cm² with diameter 53 or 63 mm.